The non-return valve is an anti-flooding device that closes automatically when a backflow of the sewer system occurs and allows a return to normal drainage when the backflow ceases.
Code | Color | ø mm | ||||
NRO50G | Grey RAL 7037 | 50 |
● The valve is to be installed directly on the discharge pipe
● Place the valve inside a well to facilitate inspection and maintenance
● Respect the direction of flow indicated on the cover by installing the socket upstream
● The body of the valve must be flat in the direction perpendicular to the flow and with a slope maximum of 2.5°
● The pipes and fittings that can be used are those complying with European standards and it is recommended that the normal outlet dimensions are not smaller than the inlet ones
● Inspection of the device should be carried out at least twice a year via the control screw cap, maintenance for restoring the moving part by disassembling, cleaning and replacing parts should be performed by experienced personnel
ø 50 mm